Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction


KIPS Transactions on Software and Data Engineering, Vol. 12, No. 7, pp. 315-324, Jul. 2023
https://doi.org/10.3745/KTSDE.2023.12.7.315,   PDF Download:
Keywords: AR, Rehabilitation, Contents, Whole-Body, Interaction
Abstract

A simple and accurate whole body rehabilitation interaction technology using immersive digital content is needed for elderly patients with steadily increasing age-related diseases. In this study, we introduce whole-body interaction technology using HoloLens and Kinect for this purpose. To achieve this, we propose three coordinate transformation methods: mesh feature point-based transformation, AR marker-based transformation, and body recognition-based transformation. The mesh feature point-based transformation aligns the coordinate system by designating three feature points on the spatial mesh and using a transform matrix. This method requires manual work and has lower usability, but has relatively high accuracy of 8.5mm. The AR marker-based method uses AR and QR markers recognized by HoloLens and Kinect simultaneously to achieve a compliant accuracy of 11.2mm. The body recognition-based transformation aligns the coordinate system by using the position of the head or HMD recognized by both devices and the position of both hands or controllers. This method has lower accuracy, but does not require additional tools or manual work, making it more user-friendly. Additionally, we reduced the error by more than 10% using RANSAC as a post-processing technique. These three methods can be selectively applied depending on the usability and accuracy required for the content. In this study, we validated this technology by applying it to the “Thunder Punch” and rehabilitation therapy content.


Statistics
Show / Hide Statistics

Statistics (Cumulative Counts from September 1st, 2017)
Multiple requests among the same browser session are counted as one view.
If you mouse over a chart, the values of data points will be shown.


Cite this article
[IEEE Style]
H. Kim, D. Kim, D. Lee, K. Lee, N. Baek, "Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction," KIPS Transactions on Software and Data Engineering, vol. 12, no. 7, pp. 315-324, 2023. DOI: https://doi.org/10.3745/KTSDE.2023.12.7.315.

[ACM Style]
Hangkee Kim, Daehwan Kim, Dongchun Lee, Kisuk Lee, and Nakhoon Baek. 2023. Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction. KIPS Transactions on Software and Data Engineering, 12, 7, (2023), 315-324. DOI: https://doi.org/10.3745/KTSDE.2023.12.7.315.